Anwendbarkeit der angiographischen CT in der periinterventionellen Bildgebung

Ein Vergleich mit der Multidetektor-Spiral-CT

dc.contributor.advisorKnauth, Michael Prof. Dr.de
dc.contributor.authorPsychogios, Marios-Nikosde
dc.date.accessioned2013-07-02T09:23:23Zde
dc.date.available2013-07-15T22:50:05Zde
dc.date.issued2013-07-02de
dc.identifier.urihttp://hdl.handle.net/11858/00-1735-0000-0001-BAA0-3de
dc.identifier.urihttp://dx.doi.org/10.53846/goediss-3917
dc.language.isodeude
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/
dc.subject.ddc610de
dc.titleAnwendbarkeit der angiographischen CT in der periinterventionellen Bildgebungde
dc.title.alternativeEin Vergleich mit der Multidetektor-Spiral-CTde
dc.typedoctoralThesisde
dc.title.translatedFeasibility of Angiographic CT in Peri-Interventional Diagnostic Imagingde
dc.contributor.refereeKnauth, Michael Prof. Dr.de
dc.date.examination2013-07-08de
dc.description.abstractengBACKGROUND AND PURPOSE: The ability to perform neuroimaging on the angiography suite is important in making decisions during neurointerventions. Our aim was the evaluation of ACT as a fast available diagnostic tool during and after neuroendovascular procedures and the comparison of ACT with postinterventional MDCT. MATERIALS AND METHODS: Eighty-four peri-interventional ACT acquisitions were obtained and evaluated: 38 after coil embolization of cerebral aneurysms, 16 after intracranial angioplasty with stent placement, and 30 after endovascular mechanical thrombectomy and lysis. Interventions and ACTs were performed on a biplane angiography system equipped with flat panel detectors. Postprocessing was performed on a dedicated workstation, and multiplanar reformations were generated. Reference studies were performed on a 16- or 128-section MDCT scanner. All studies were independently evaluated by 3 blinded neuroradiologists. The Wilcoxon test was applied for the statistical analysis. RESULTS: ACT and MDCT images were of equal diagnostic quality in most cases related to the supratentorial ventricular system and the detection of hemorrhages (subarachnoidal, intraparenchymal, and intraventricular). Regarding the supratentorial ventricular system, an adequate diagnostic quality was assigned to 94% of the ACT acquisitions. For the detection of hemorrhage, no statistically significant difference was noted between ACT and MDCT. However, for the infratentorial region, ACT performed relatively poorly compared with MDCT. The diagnostic evaluation of gray matter (basal ganglia, insular cortex, and central cortex) by ACT is not sufficient, with 20% of the acquisitions scoring a diagnostic value. CONCLUSIONS: After neuroendovascular procedures and within the angiography suite, ACT enables an immediate detection of peri-interventional hemorrhage or hydrocephalus. However, for the detection of cerebral infarction, ACT is not yet reliable.de
dc.contributor.coRefereeMielke, Dorothee PD Dr.de
dc.title.alternativeTranslatedA Comparative Study with Multidetector CTde
dc.subject.engangiographic CT, periintervetnional imaging, aneurysm treatment, multidetector CT, stroke imagingde
dc.identifier.urnurn:nbn:de:gbv:7-11858/00-1735-0000-0001-BAA0-3-8de
dc.affiliation.instituteMedizinische Fakultätde
dc.subject.gokfullMedizin (PPN619874732)de
dc.description.embargoed2013-07-15de