dc.contributor.advisor Sennhenn-Kirchner, Sabine PD Dr.
dc.contributor.author Mehnert, Julika
dc.date.accessioned 2013-09-12T05:56:35Z
dc.date.available 2013-10-08T22:50:04Z
dc.date.issued 2013-09-12
dc.identifier.uri http://hdl.handle.net/11858/00-1735-0000-0001-BB79-6
dc.language.iso deu de
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/
dc.subject.ddc 610 de
dc.title Untersuchung der Formstabilität verschiedener Kunststoffe zur Herstellung steriler dentaler Implantatschablonen de
dc.type doctoralThesis de
dc.title.translated Study of the form stability of various plastics for the production of sterile dental implant drilling templates de
dc.contributor.referee Sennhenn-Kirchner, Sabine PD Dr.
dc.date.examination 2013-10-01
dc.description.abstracteng The aim of the study was to evaluate different dental plastics for the possibility of sterilization and for form stability in order for them to be used (law-compliant) as an implant drilling template. Five plastics were examined: Impla Steri Guide, Eclipse, Primotec, Palavit G and Orthocryl. 15 test bodies were made of each plastic, each in the form of a horseshoe, and equipped with five metal pins. Those pins enable the measuring of distance and surface before and after sterilization with an optical method. The company producing Impla Steri Guide had already been advertising the possibility of sterilization at the time of investigation but without providing any specific information or scientific studies to back up this claim. Therefore we examined its form stability and compared it with four other plastics. The results of the optical measurements shows a form variation for all plastics, in particular Orthocryl and Palavit G. After sterilization, all surfaces changed as did distances between metal pins. Almost all test bodies of Impla Steri Guide (15/15), of Primotec (14/15) and of Eclipse (14/15) fitted on the source form. The results are of clinical relevance because the Medicinal Products Act demands the sterilization of implant drilling templates. On the basis of our results, three of the measured plastics (Impla Steri Guide, Eclipse and Primotec) can be used as implant drilling templates due to the fact that changes are minimal (between 0,5 mm and -0,5 mm). Future research should investigate more plastics to be used as implant drilling templates. de
dc.contributor.coReferee Gersdorff, Nikolaus PD Dr.
dc.subject.ger Sterilisation de
dc.subject.ger Formstabilität de
dc.subject.ger Kunststoff de
dc.subject.ger Medizinproduktegesetz de
dc.subject.ger Bohrschablone de
dc.subject.eng implant drilling templates de
dc.subject.eng form stability de
dc.subject.eng Medicinal Products Act de
dc.subject.eng plastics de
dc.subject.eng sterilization de
dc.identifier.urn urn:nbn:de:gbv:7-11858/00-1735-0000-0001-BB79-6-5
dc.affiliation.institute Medizinische Fakultät de
dc.subject.gokfull Medizin (PPN619874732) de
dc.description.embargoed 2013-10-08