Zur Kurzanzeige

Quantifizierung von Sevofluran an Anästhesiearbeitsplätzen mittels Ionenmobilitätsspektrometrie

dc.contributor.advisorQuintel, Michael Prof. Dr.
dc.contributor.authorWeigel, Cathrin
dc.date.accessioned2014-07-28T08:45:31Z
dc.date.available2014-09-08T22:50:06Z
dc.date.issued2014-07-28
dc.identifier.urihttp://hdl.handle.net/11858/00-1735-0000-0022-5F34-4
dc.identifier.urihttp://dx.doi.org/10.53846/goediss-4613
dc.language.isodeude
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/
dc.subject.ddc610de
dc.titleQuantifizierung von Sevofluran an Anästhesiearbeitsplätzen mittels Ionenmobilitätsspektrometriede
dc.typedoctoralThesisde
dc.title.translatedQuantification of occupational exposure to sevoflurane in anaesthesia workplaces using multi- capillary column- ion mobility spectrometry (MCC- IMS)de
dc.contributor.refereeHeutelbeck, Astrid PD Dr.
dc.date.examination2014-08-11
dc.description.abstractengBackground: Occupational exposure to sevoflurane has the potential to cause health damage in hospital personnel. Workplace contamination with the substance is mostly assessed using photoacoustic infrared spectrometry or flame ionization detector. Multi-capillary column-ion mobility spectrometry (MCC-IMS) could be an alternative technology for the quantification of sevoflurane in the room air and even be more accurate because of potentially lower detection limits. In principal other volatile anaesthetics could be detected and quantified simultaneously by using MCC-IMS. Objective: To test the hypothesis that MCC-IMS is able to detect and monitor very low concentrations of sevoflurane in a hospital setting. To evaluate the exposure of hospital personnel to sevoflurane during paediatric anaesthesia and in the post anaesthesia care unit (PACU). Design: Observational study. Setting: University Medical Centre of Göttingen in Germany: Paediatric dental surgical theatre (from June 19th 2012 until August 7th 2012); PACU (from October 27th 2009 until October 29th 2009). Main outcome measures: The limits of detection (LOD) and quantification (LOQ) of the MCC-IMS for sevoflurane and the sevoflurane exposure of hospital personnel measured by MCC-IMS and calculated as time-weighted average (TWA) values. Results: The LOD was 0.0068 ppbv and the LOQ was 0.0189 ppbv. During paediatric anaesthesia the mean sevoflurane concentration was 0,4602ppmv (0,0754 – 3,1473ppmv) with TWA values between 0,0052 and 0,0365ppmv. In the PACU the mean sevoflurane concentration was 0,0279ppmv (0,008 – 0,1702ppmv) and TWA values reached from 0,0093 to 0,0967ppmv. Conclusion: The detection and the quantification of sevoflurane by the use of MCC-IMS is possible. It is a reliable technology for monitoring sevoflurane concentrations at anaesthesia workplaces and has a particular strength in quantifying low-level contaminations of sevoflurane. The exposure of the personnel working in these areas did not exceed recommended limits and therefore adverse health effects are unlikely.de
dc.contributor.coRefereeMausberg, Rainer Prof. Dr.
dc.subject.gerSevoflurande
dc.subject.gerIonenmobilitätsspektrometriede
dc.subject.engSevofluranede
dc.subject.engMulti capillary column ion mobility spectrometryde
dc.identifier.urnurn:nbn:de:gbv:7-11858/00-1735-0000-0022-5F34-4-2
dc.affiliation.instituteMedizinische Fakultätde
dc.subject.gokfullMedizin (PPN619874732)de
dc.subject.gokfullAnästhesiologie / Intensivmedizin / Notfallmedizin / Analgesie - Allgemein- und Gesamtdarstellungen (PPN619875917)de
dc.description.embargoed2014-08-18
dc.identifier.ppn791336379


Dateien

Thumbnail

Das Dokument erscheint in:

Zur Kurzanzeige