• Deutsch
    • English
  • English 
    • Deutsch
    • English
  • Login
Item View 
  •   Home
  • Medizin
  • Human- und Zahnmedizin
  • Item View
  •   Home
  • Medizin
  • Human- und Zahnmedizin
  • Item View
JavaScript is disabled for your browser. Some features of this site may not work without it.

Kraft- und Drehmomentabgabe thermoplastisch geformter Schienen bei Rotationsbewegung eines Unterkieferfrontzahnes

Forces and moments generated by thermoplastic appliances during rotation of a lower lateral incisor

by Gesa Gruber
Doctoral thesis
Date of Examination:2015-07-22
Date of issue:2015-06-12
Advisor:PD Dr. Wolfram Hahn
Referee:Prof. Dr. Philipp Franz Meyer-Marcotty
Referee:Prof. Dr. Margarete Schön
crossref-logoPersistent Address: http://dx.doi.org/10.53846/goediss-5131

 

 

Files in this item

Name:Bessau_Diss_sub.pdf
Size:39.7Mb
Format:PDF
ViewOpen

The following license files are associated with this item:


Abstract

English

Forces and moments generated by thermoplastic appliances during rotation of a lower lateral incisor Removable thermoplastic aligners are used among many different orthodontic appliances to correct tooth displacement. The range of indications for orthodontic treatment with aligners is limited. However, clinical studies have demonstrated that the rotation of incisors, which was investigated in the present study, can be carried out successfully using thermoplastic aligners. Irrespective of the type of appliance for an ideal orthodontic therapy, forces should be applied to maximise tooth movement and minimise tissue damage. Therefore, the knowledge of strength delivery is inevitable. The present study aimed to measure initial forces (Fz) and moments (Tz) delivered by thermoplastic appliances from four different materials (Biolon®, Erkodur®, Ideal Clear®, Ideal Comfort®) acting on a lower lateral incisor during rotation around its central axis. The appearance of intrusive forces (Fz) has always been observed beside the intended forces for orthodontic tooth rotation. The Forces (Fz) and moments (Tz) were investigated under the influence of deflection in clockwise (- 0,157 mm and - 0,360 mm) and anticlockwise (0,157 mm and 0,360 mm) direction. The study ́s key results can be summarised as follows: Both Fz and Tz values were generally higher than the ideal force recommended for orthodontic treatment in dental literature. Biolon® delivered the highest values for Fz and Tz. The Tz values for anticlockwise rotation were higher than for clockwise rotation.
Keywords: thermoplastic appliances; forces; aligner
Schlagwörter: thermoplastisch geformte Schienen; Drehmomente; intrusive Kräfte
 

Statistik

Publish here

Browse

All of eDissFaculties & ProgramsIssue DateAuthorAdvisor & RefereeAdvisorRefereeTitlesTypeThis FacultyIssue DateAuthorAdvisor & RefereeAdvisorRefereeTitlesType

Help & Info

Publishing on eDissPDF GuideTerms of ContractFAQ

Contact Us | Impressum | Cookie Consents | Data Protection Information
eDiss Office - SUB Göttingen (Central Library)
Platz der Göttinger Sieben 1
Mo - Fr 10:00 – 12:00 h


Tel.: +49 (0)551 39-27809 (general inquiries)
Tel.: +49 (0)551 39-28655 (open access/parallel publications)
ediss_AT_sub.uni-goettingen.de
[Please replace "_AT_" with the "@" sign when using our email adresses.]
Göttingen State and University Library | Göttingen University
Medicine Library (Doctoral candidates of medicine only)
Robert-Koch-Str. 40
Mon – Fri 8:00 – 24:00 h
Sat - Sun 8:00 – 22:00 h
Holidays 10:00 – 20:00 h
Tel.: +49 551 39-8395 (general inquiries)
Tel.: +49 (0)551 39-28655 (open access/parallel publications)
bbmed_AT_sub.uni-goettingen.de
[Please replace "_AT_" with the "@" sign when using our email adresses.]