• Deutsch
    • English
  • English 
    • Deutsch
    • English
  • Login
Item View 
  •   Home
  • Medizin
  • Human- und Zahnmedizin
  • Item View
  •   Home
  • Medizin
  • Human- und Zahnmedizin
  • Item View
JavaScript is disabled for your browser. Some features of this site may not work without it.

Klinische Resultate dentaler Implantate im augmentierten Unterkiefer nach Zylinderinversionsplastik

Clinical results of dental implants in augmented mandibular ridge using Upside Down Cylinder Technique

by Thomas Lautenschläger
Doctoral thesis
Date of Examination:2017-04-25
Date of issue:2017-03-08
Advisor:Prof. Dr. Dr. Wilfried Engelke
Referee:Prof. Dr. Dr. Wilfried Engelke
Referee:Prof. Dr. Philipp Franz Meyer-Marcotty
crossref-logoPersistent Address: http://dx.doi.org/10.53846/goediss-6165

 

 

Files in this item

Name:Dissertation_final_SUB_Webanzeige.pdf
Size:7.62Mb
Format:PDF
ViewOpen

The following license files are associated with this item:


Abstract

English

Purpose: In order to achieve good long-term results from dental implant therapy a sufficient amount of bone is needed around the correct implant position. Therefore, various procedures were introduced to augment the horizontally deficient mandibular ridge. The Upside Down Cylinder Technique makes use of localized autologous bone transfer in order to prevent the otherwise inevitable grafting procedure. In this retrospective study, clinical results and oral health related quality of life (OHRQoL) are being reported. Method: 44 Patients received horizontal bone augmentation and 29 Patients (22 female, seven male) with 43 implants could be followed up (dropout rate 34 %). The mean observation time was 93,6 +/- 36,3 months. Periimplant bone resorption (PBR), implant stability, periodontal probing depth (PPD), gingival recession (GR), implant survival, implant success and the state of OHRQoL were evaluated, respectively. Results: Within the observation period two implants were lost due to biological complications. This study shows an implant survival rate of 93 %. The implant success rate was 88,1 % according to Jahn/d’Hoedt criteria and 76,2 % according to Naert/Snauwaert criteria regarding patient level observation. Mean PBR was 2,57 +/- 1,93 mm, PPD accounted to 2,68 +/- 0,91 mm and GR was 0,75 +/- 1,26 mm. In order to assess patients OHRQOL, the Oral Health Impact Profile (OHIP) was used. Separated by prostetic indication classes, patients with installed FPD scored 9,2; patients with implant retained removable partial dentures and total prostheses scored 15,5 and 17,3; respectively. Corresponding scores were 30, 20 and 20 percentiles higher than median of reference values from non - treatment - seeking patients Conclusion: Upside Down Cylinder Technique delivers comparable implant long-term results compared to other autologous augmentation procedures without having to raise a flap for bone grafting. OHRQOL was high compared to reference values from non - treatment - seeking patients. Patients satisfaction and recommendation was also high. This study suggests a higher success rate in the posterior mandibular ridge.
Keywords: Dental implants; bone augmentation; mandibular ridge augmentation; oral health related quality of life; Upside Down Cylinder Technique; grafting technique; long-term success rate; bone grafting
Schlagwörter: Dentale Implantate; Knochenaugmentation; Kieferkammaufbau; Mundgesundheitsbezogene Lebensqualität; Zylinderinversionsplastik; Erfolgsrate Implantate
 

Statistik

Publish here

Browse

All of eDissFaculties & ProgramsIssue DateAuthorAdvisor & RefereeAdvisorRefereeTitlesTypeThis FacultyIssue DateAuthorAdvisor & RefereeAdvisorRefereeTitlesType

Help & Info

Publishing on eDissPDF GuideTerms of ContractFAQ

Contact Us | Impressum | Cookie Consents | Data Protection Information
eDiss Office - SUB Göttingen (Central Library)
Platz der Göttinger Sieben 1
Mo - Fr 10:00 – 12:00 h


Tel.: +49 (0)551 39-27809 (general inquiries)
Tel.: +49 (0)551 39-28655 (open access/parallel publications)
ediss_AT_sub.uni-goettingen.de
[Please replace "_AT_" with the "@" sign when using our email adresses.]
Göttingen State and University Library | Göttingen University
Medicine Library (Doctoral candidates of medicine only)
Robert-Koch-Str. 40
Mon – Fri 8:00 – 24:00 h
Sat - Sun 8:00 – 22:00 h
Holidays 10:00 – 20:00 h
Tel.: +49 551 39-8395 (general inquiries)
Tel.: +49 (0)551 39-28655 (open access/parallel publications)
bbmed_AT_sub.uni-goettingen.de
[Please replace "_AT_" with the "@" sign when using our email adresses.]