Show simple item record

Evaluation der Abzugskräfte von implantatgetragenen Kronengerüsten auf Zirkoniumdioxidbasis in Abhängigkeit von der Abutmentgeometrie und Zementierungsart

dc.contributor.advisorRödiger, Matthias PD Dr.
dc.contributor.authorKloß, Janine Lydia
dc.date.accessioned2015-11-27T10:05:18Z
dc.date.available2015-12-14T23:50:05Z
dc.date.issued2015-11-27
dc.identifier.urihttp://hdl.handle.net/11858/00-1735-0000-0028-8646-F
dc.identifier.urihttp://dx.doi.org/10.53846/goediss-5395
dc.language.isodeude
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subject.ddc610de
dc.titleEvaluation der Abzugskräfte von implantatgetragenen Kronengerüsten auf Zirkoniumdioxidbasis in Abhängigkeit von der Abutmentgeometrie und Zementierungsartde
dc.typedoctoralThesisde
dc.title.translatedEvaluation of detachment forces of implant-based crown frames on a zirconium dioxide basis as a function of abutment geometry and manner of cementationde
dc.contributor.refereeRödiger, Matthias PD Dr.
dc.date.examination2015-12-07
dc.description.abstractengPurpose: In this in-vitro study the influence of two different adhesive composites and their retention on two different abutments was examined. Materials and methods: Forty implants were embedded in resin blocks. Forty titanium abutments were fabricated: twenty with a height of 4,31 mm and twenty with a height of 6,79 mm. The zirconia crowns were manufactured through the CAD/CAM system and cemented with RelyX™ Unicem and Multilink Automix. All samples were thermally cycled to simulate the oral conditions. The decementing was executed in an universal testing machine and the results were statistically evaluated with ANOVA. Results: RelyX™ Unicem showed the highest level of retentiveness. The retention force between the crown and the abutment was even higher then the screw connection, so that the screw connection was broken. However, the samples of Multilink Automix were all decementated. Conclusion: The abutment height influences the retention independent on the luting agent. A higher abutment results in better retention. Both luting agents can be used for the definitive cementation of zirconia crowns. RelyX™ Unicem shows that a conditioning oft the abutment and crown is not mandatory to receive good results.de
dc.contributor.coRefereeHülsmann, Michael Prof. Dr.
dc.subject.gerZahnmedizinde
dc.subject.gerImplantatde
dc.subject.gerKronede
dc.subject.gerZirkoniumdioxidde
dc.subject.gerAbzugskräftede
dc.subject.gerMultilink Automixde
dc.subject.gerRelyX Unicemde
dc.subject.gerAdhäsive Zementede
dc.subject.engDentistryde
dc.subject.engImplantde
dc.subject.engCrownde
dc.subject.engZirconium dioxidede
dc.subject.engdetachment forcede
dc.subject.engLuting agentde
dc.subject.engMultilink Automixde
dc.subject.engRelyX Unicemde
dc.subject.engRetentionde
dc.identifier.urnurn:nbn:de:gbv:7-11858/00-1735-0000-0028-8646-F-6
dc.affiliation.instituteMedizinische Fakultätde
dc.subject.gokfullZahn-, Mund- und Kieferheilkunde - Allgemein- und Gesamtdarstellungen (PPN619876360)de
dc.description.embargoed2015-12-14
dc.identifier.ppn84107688X


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record