Zur Kurzanzeige

Klinische Nachuntersuchung von implantatgestützten Einzelkronen mit CAD/CAM gefertigten Abutments – 5-Jahres-Ergebnisse

dc.contributor.advisorRinke, Sven Prof. Dr.
dc.contributor.authorBrack, Christoph
dc.date.accessioned2022-07-19T10:39:55Z
dc.date.available2022-08-16T00:50:21Z
dc.date.issued2022-07-19
dc.identifier.urihttp://resolver.sub.uni-goettingen.de/purl?ediss-11858/14163
dc.identifier.urihttp://dx.doi.org/10.53846/goediss-9358
dc.language.isodeude
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.subject.ddc610de
dc.titleKlinische Nachuntersuchung von implantatgestützten Einzelkronen mit CAD/CAM gefertigten Abutments – 5-Jahres-Ergebnissede
dc.typedoctoralThesisde
dc.title.translatedClinical follow-up of implant-supported single crowns with CAD/CAM fabricated abutments – 5-year resultsde
dc.contributor.refereeRinke, Sven Prof. Dr.
dc.date.examination2022-08-09de
dc.description.abstractgerZielsetzung: Das Ziel der vorliegenden prospektiven und praxisbasierten Studie war es, den Einfluss von individuell hergestellten CAD/CAM-Abutments auf die technischen Komplikationen von provisorisch zementierten vollkeramischen und metallkeramischen Einzelkronen im Seitenzahnbereich in einem Beobachtungszeitraum von > 5 Jahren zu untersuchen. Methode: In einer privaten Zahnarztpraxis (Hanau, Deutschland) wurden 74 Patienten mit 93 CAD/CAM-Titanabutments und metallkeramischen Einzelkronen sowie 30 CAD/CAM-Zirkonoxidkeramikabutments mit vollkeramischen Einzelkronen versorgt und jährlich hinsichtlich technischer Komplikationen und Verluste (survival) nachuntersucht. Aus den erhobenen Daten wurden die Inzidenzen und jährlichen Eventraten von technischen Komplikationen sowie die Erfolgs- und Überlebensraten mittels Ereigniszeitanalyse durch die Kaplan-Meier-Methode ermittelt. Zudem wurde unter Anwendung der Cox-Regressionsanalyse untersucht, ob die Implantatposition und die zu ersetzende Zahnform (Molar/Prämolar) einen Einfluss auf die Erfolgsraten nehmen. Ergebnisse: Die durchschnittliche Beobachtungszeit betrug 62 ± 16 Monate. Zur Abschlussuntersuchung konnten 59 Patienten (32 weiblich, 27 männlich, 35 bis 78 Jahre) mit 71 CAD/CAM-Titanabutments und 20 CAD/CAM-Zirkonoxidkeramikabutments nachuntersucht werden. Innerhalb der Gruppe der CAD/CAM-Titanabutments ergab sich aufgrund von zwei Abutmentfrakturen eine 6-Jahres-Überlebensrate von 97 %. Aufgrund eines Approximalkontaktverlustes resultierte die Neuanfertigung einer metallkeramischen Einzelkrone. Die 6-Jahres-Überlebensrate für metallkeramische Einzelkronen beträgt 99 %, die der vollkeramischen Einzelkronen 100 %. Innerhalb der Beobachtungszeit sind sechs technische Komplikationen aufgetreten: Retentionsverlust der Krone (2), Verblendkeramikfraktur (1), Abutmentschraubenlockerung (1) und Verlust des Approximalkontaktes (2). Insgesamt ergab sich eine jährliche Gesamtfehlerrate von 1,32 %. Alle technischen Komplikationen sind in der Gruppe der CAD/CAM-Titanabutments mit metallkeramischen Einzelkronen aufgetreten (6-Jahres-Erfolgsrate 86 %). Die Cox-Regressionsanalyse zeigte, dass weder die Position des Implantates noch die zu ersetzende Zahnform (Molar/Prämolar) einen statistisch signifikanten Einfluss auf die Erfolgsraten der Suprakonstruktionen nehmen. Schlussfolgerungen: Auf Basis der vorliegenden Studie können individuelle einteilige CAD/CAM-Titanabutments und zweiteilige CAD/CAM-Zirkonoxidkeramikabutments mit provisorisch zementierten Einzelkronen im Seitenzahnbereich über einen durchschnittlichen Beobachtungszeitraum von fünf Jahren mit ausreichender klinischer Sicherheit verwendet werden. Tendenziell lassen sich weniger Verblendkeramikfrakturen und Retentionsverluste bei der Verwendung von individuellen CAD/CAM-Abutments im Vergleich zu konfektionierten Abutments konstatieren.de
dc.description.abstractengObjectives: The aim of the present prospective and practice-based study was to investigate the influence of individually fabricated CAD/CAM abutments on the technical complications of provisionally cemented all-ceramic and metal-ceramic single crowns in the posterior region over an observation period of > 5 years. Material und Methods: In a private dental practice (Hanau, Germany), 74 patients were restored with 93 CAD/CAM titanium abutments and metal-ceramic single crowns and 30 CAD/CAM zirconia ceramic abutments with all-ceramic single crowns and followed up annually with regard to technical complications and losses (survival). From the data collected, the incidences and annual event rates of technical complications as well as the success and survival rates were determined using event time analysis by the Kaplan-Meier method. In addition, Cox regression analysis was used to investigate whether implant position and the tooth shape to be replaced (molar/premolar) have an influence on success rates. Results: The average observation period was 62 ± 16 months. At the final examination, 59 patients (32 female, 27 male, 35 to 78 years) with 71 CAD/CAM titanium abutments and 20 CAD/CAM zirconia ceramic abutments were followed up. Within the CAD/CAM titanium abutment group, there was a 6-year survival rate of 97% due to two abutment fractures. Due to a loss of proximal contact, this resulted in the fabrication of a new metal-ceramic single crown. The 6-year survival rate for metal-ceramic single crowns is 99%, that of all-ceramic single crowns 100%. Six technical complications occurred within the observation period: Crown retention loss (2), ceramic veneer fracture (1), abutment screw loosening (1), and loss of proximal contact (2). Overall, the total annual failure rate was 1.32%. All technical complications occurred in the CAD/CAM titanium abutment group with metal-ceramic single crowns (6-year success rate 86%). The Cox regression analysis showed that neither the position of the implant nor the tooth shape to be replaced (molar/premolar) had a statistically significant influence on the success rates of the superstructures. Conclusions: Based on the present study, individual one-piece CAD/CAM titanium abutments and two-piece CAD/CAM zirconia ceramic abutments with provisionally cemented single crowns in the posterior region can be used with sufficient clinical safety over an average observation period of five years. The customized CAD/CAM abutments tend to have fewer ceramic veneer fractures and retention losses compared to the prefabricated Abutments.de
dc.contributor.coRefereeHülsmann, Michael Prof. Dr.
dc.subject.gerimplantatgestützte Einzelkronede
dc.subject.gerCAD/CAM gefertigte Abutmentsde
dc.subject.gerIndividuelles Abutmentde
dc.subject.gerÜberlebensratede
dc.subject.gerErfolgsratede
dc.subject.gerTechnische Komplikationende
dc.subject.engImplant-supported single crownde
dc.subject.engCAD/CAM fabricated abutmentsde
dc.subject.engcustomized abutmentde
dc.subject.engsurvival ratede
dc.subject.engsuccess ratede
dc.subject.engtechnical complicationsde
dc.identifier.urnurn:nbn:de:gbv:7-ediss-14163-2
dc.affiliation.instituteMedizinische Fakultätde
dc.subject.gokfullProthetik (PPN619876417)de
dc.subject.gokfullZahn-, Mund- und Kieferheilkunde - Allgemein- und Gesamtdarstellungen (PPN619876360)de
dc.description.embargoed2022-08-16de
dc.identifier.ppn1811121039
dc.notes.confirmationsentConfirmation sent 2022-07-19T10:45:02de


Dateien

Thumbnail

Das Dokument erscheint in:

Zur Kurzanzeige