• Deutsch
    • English
  • Deutsch 
    • Deutsch
    • English
  • Einloggen
Dokumentanzeige 
  •   Startseite
  • Medizin
  • Human- und Zahnmedizin
  • Dokumentanzeige
  •   Startseite
  • Medizin
  • Human- und Zahnmedizin
  • Dokumentanzeige
JavaScript is disabled for your browser. Some features of this site may not work without it.

Ultraschall-gesteuerte Freisetzung von an Nanopartikeln gebundenem Nimodipin und deren Anwendung zur Therapie von experimentell erzeugten Vasospasmen an der Chorioallantoismembran des embryonalen Eis

von Katja Döring geb. Döring
Dissertation
Datum der mündl. Prüfung:2022-12-13
Erschienen:2022-12-05
Betreuer:PD Dr. Vesna Malinova
Gutachter:PD Dr. Vesna Malinova
Gutachter:Prof. Dr. Thorsten Roland Döppner
crossref-logoZum Verlinken/Zitieren: http://dx.doi.org/10.53846/goediss-9606

 

 

Dateien

Name:Doering_Katja_PlagCheck_Kramannchecked_SUB.pdf
Size:2.18Mb
Format:PDF
ViewOpen

Lizenzbestimmungen:


Zusammenfassung

Englisch

Nimodipine prevents cerebral vasospasm and improves functional outcome after aneurysmal subarachnoid hemorrhage (aSAH). The beneficial effect is limited by low oral bioavailability of nimodipine, which resulted in an increasing use of nanocarriers with sustained intrathecal drug release in order to overcome this limitation. However, this approach facilitates only a continuous and not an on-demand nimodipine release during the peak time of vasospasm development. In this study, we aimed to assess the concept of controlled drug release from nimodipine-loaded copolymers by ultrasound application in the chicken chorioallantoic membrane (CAM) model. Nimodipine-loaded copolymers were produced with the direct dissolution method. Vasospasm of the CAM vessels was induced by means of ultrasound (Physiomed, continuous wave, 3MHz, 1.0W/cm2). The ultrasound-mediated nimodipine release (Physiomed, continuous wave, 1MHz, 1.7W/cm2) and its effect on the CAM vessels were evaluated. Measurements of vessel diameter before and after ultrasound-induced nimodipine release were performed using ImageJ. The CAM model could be successfully carried out in all 25 eggs. After vasospasm induction and before drug release, the mean vessel diameter was at 57% (range 44–61%) compared to the baseline diameter (set at 100%). After ultrasound-induced drug release, the mean vessel diameter of spastic vessels increased again to 89% (range 83–91%) of their baseline diameter, which was significant (p = 0.0002). We were able to provide a proof of concept for invivo vasos-pasm induction by ultrasound application in the CAM model and subsequent resolution by ultrasound-mediated nimodipine release from nanocarriers. This concept merits further evaluation in a rat SAH model.
Keywords: vasospam, SAB, chorioallantoic membran, aneurysm
 

Statistik

Hier veröffentlichen

Blättern

Im gesamten BestandFakultäten & ProgrammeErscheinungsdatumAutorBetreuer & GutachterBetreuerGutachterTitelTypIn dieser FakultätErscheinungsdatumAutorBetreuer & GutachterBetreuerGutachterTitelTyp

Hilfe & Info

Publizieren auf eDissPDF erstellenVertragsbedingungenHäufige Fragen

Kontakt | Impressum | Cookie-Einwilligung | Datenschutzerklärung
eDiss - SUB Göttingen (Zentralbibliothek)
Platz der Göttinger Sieben 1
Mo - Fr 10:00 – 12:00 h


Tel.: +49 (0)551 39-27809 (allg. Fragen)
Tel.: +49 (0)551 39-28655 (Fragen zu open access/Parallelpublikationen)
ediss_AT_sub.uni-goettingen.de
[Bitte ersetzen Sie das "_AT_" durch ein "@", wenn Sie unsere E-Mail-Adressen verwenden.]
Niedersächsische Staats- und Universitätsbibliothek | Georg-August Universität
Bereichsbibliothek Medizin (Nur für Promovierende der Medizinischen Fakultät)
Robert-Koch-Str. 40
Mon – Fri 8:00 – 24:00 h
Sat - Sun 8:00 – 22:00 h
Holidays 10:00 – 20:00 h
Tel.: +49 551 39-8395 (allg. Fragen)
Tel.: +49 (0)551 39-28655 (Fragen zu open access/Parallelpublikationen)
bbmed_AT_sub.uni-goettingen.de
[Bitte ersetzen Sie das "_AT_" durch ein "@", wenn Sie unsere E-Mail-Adressen verwenden.]