Untersuchung der mechanischen Dyssynchronie bei Patienten mit Ebstein-Anomalie
by Simon Welsch née Usenbenz
Date of Examination:2023-07-13
Date of issue:2023-07-13
Advisor:Prof. Dr. Dr. Andreas Schuster
Referee:Prof. Dr. Dr. Andreas Schuster
Referee:PD Dr. Heike Schneider
Files in this item
Name:Diss Simon Welsch.pdf
Size:4.23Mb
Format:PDF
Abstract
English
Background: Disease progression and heart failure development in Ebstein’s Anomaly (EA) of the tricuspid valve is characterized by both right and left ventricular (LV) deterioration. The mechanisms underlying LV dysfunction and their role in heart failure development are incompletely understood. We hypothesized that LV dyssynchrony and impaired torsion and recoil mechanics induced by paradoxical movement of the basal septum may play a role in heart failure development. Methods: 31 EA patients and 31 matched controls underwent prospective cardiovascular magnetic resonance (CMR). CMR feature tracking (CMR-FT) was performed on apical, midventricular and basal short-axis and 4D–volume analysis was performed using three long-axis views and a short axis cine stack employing dedicated software. Circumferential uniformity ratio estimates (CURE) time-to-peak-based circumferential systolic dyssynchrony index (C-SDI), 4D volume analysis derived SDI (4D–SDI), torsion (Tor) and systolic (sysTR) and diastolic torsion rate (diasTR) were calculated for the LV. QRS duration, brain natriuretic peptide, NYHA and Total R/L-Volume Index (R/L Index) were obtained. Results: EA patients (31.5 years; controls 31.4 years) had significantly longer QRS duration (123.35 ms ± 26.36 vs. 97.33 ms ± 11.89 p < 0.01) and showed more LV dyssynchrony (4D–SDI 7.60% ± 4.58 vs. 2.54% ± 0.62, p < 0.001; CURE 0.77 ± 0.05 vs. 0.86 ± 0.03, p < 0.001; C-SDI 7.70 ± 3.38 vs. 3.80 ± 0.91, p = 0.001). There were significant associations of LV dyssynchrony with heart failure parameters and QRS duration. Although torsion and recoil mechanics did not differ significantly (p > 0.05) there was an association of torsion and recoil mechanics with dyssynchrony parameters CURE (sysTR r = −0.426; p = 0.017, diasTR r = 0.419; p = 0.019), 4D–SDI (sysTR r = 0.383; p = 0.044) and C-SDI (diasTR r = −0.364; p = 0.044). Conclusions: EA is characterized by LV intra-ventricular dyssynchrony, which is associated with heart failure and disease severity parameters. Markers of dyssynchrony can easily be quantified from CMR-FT, and may have a role in the assessment of altered cardiac function, carrying potential management implications for EA patients.
Keywords: dyssynchrony; CMR feature tracking; Torsion and recoil; Heart failure; ebstein anomaly; Congenital heart disease