• Deutsch
    • English
  • Deutsch 
    • Deutsch
    • English
  • Einloggen
Dokumentanzeige 
  •   Startseite
  • Medizin
  • Human- und Zahnmedizin
  • Dokumentanzeige
  •   Startseite
  • Medizin
  • Human- und Zahnmedizin
  • Dokumentanzeige
JavaScript is disabled for your browser. Some features of this site may not work without it.

Analyse der In-vitro-Funktion verschiedener Anti-Siphon-Ventile in Kombination mit verschiedenen Differenzdruckventilen mit und ohne Bewegung

In vitro performance of six combinations of adjustable differential pressure valves and fixed anti siphon devices with and without vertical motion

von Pauline Röhrig
Dissertation
Datum der mündl. Prüfung:2025-01-15
Erschienen:2024-12-13
Betreuer:Prof. Dr. Veit Rohde
Gutachter:Prof. Dr. Veit Rohde
Gutachter:Prof. Dr. Bernhard Reuß
crossref-logoZum Verlinken/Zitieren: http://dx.doi.org/10.53846/goediss-10902

 

 

Dateien

Name:Röhrig_Pauline_Dissertation.pdf
Size:5.72Mb
Format:PDF
ViewOpen

Lizenzbestimmungen:


Zusammenfassung

Englisch

Shunt therapy using adjustable differential pressure valves combined with anti-siphon devices (ASDs) is a well-established approach for treating normal pressure hydrocephalus but continues to pose risks of severe complications, such as overdrainage. This study is aimed to analyze the flow characteristics of 3 commercial differential pressure valves paired with 2 different ASDs under static and dynamic conditions. The differential pressure valves proGAV 2.0 [PG], CertasPlus [CP], and HakimMedos [HM] were evaluated in combination with the gravity-regulated ASD (ShuntAssistant [SA]) and the flow-regulated ASD (SiphonGuard [SG]. Flow data was recorded at differential pressures ranging from 4 to 40 cmH₂O in both stationary setups and during vertical oscillations at frequencies of 2, 3, and 4 Hz. Additionally, the impact of inclination angles (90° vs. 60°) on flow rates was assessed. Results demonstrated that combinations with the gravity-regulated ASD allowed no or minimal flow at low differential pressures in static conditions, while a linear increase in flow occurred at higher pressures. Dynamic testing revealed significant flow increases for these combinations, proportional to oscillation frequency. In contrast, combinations with flow-regulated ASDs exhibited lower flow rates overall, and movement did not increase flow. Instead, the characteristic biphasic flow curve observed under static conditions was eliminated during motion. The distinct flow characteristics of the ASDs highlight the critical importance of selecting appropriate valve combinations for clinical applications. The findings provide valuable insights into tailoring shunt systems to individual patient needs and mitigating complications associated with movement. Further studies should build upon these results to optimize shunt systems and reduce the incidence of overdrainage in clinical practice.
Keywords: hydrocephalus
 

Statistik

Hier veröffentlichen

Blättern

Im gesamten BestandFakultäten & ProgrammeErscheinungsdatumAutorBetreuer & GutachterBetreuerGutachterTitelTypIn dieser FakultätErscheinungsdatumAutorBetreuer & GutachterBetreuerGutachterTitelTyp

Hilfe & Info

Publizieren auf eDissPDF erstellenVertragsbedingungenHäufige Fragen

Kontakt | Impressum | Cookie-Einwilligung | Datenschutzerklärung | Barrierefreiheit
eDiss - SUB Göttingen (Zentralbibliothek)
Platz der Göttinger Sieben 1
Mo - Fr 10:00 – 12:00 h


Tel.: +49 (0)551 39-27809 (allg. Fragen)
Tel.: +49 (0)551 39-28655 (Fragen zu open access/Parallelpublikationen)
ediss_AT_sub.uni-goettingen.de
[Bitte ersetzen Sie das "_AT_" durch ein "@", wenn Sie unsere E-Mail-Adressen verwenden.]
Niedersächsische Staats- und Universitätsbibliothek | Georg-August Universität
Bereichsbibliothek Medizin (Nur für Promovierende der Medizinischen Fakultät)
Robert-Koch-Str. 40
Mon – Fri 8:00 – 24:00 h
Sat - Sun 8:00 – 22:00 h
Holidays 10:00 – 20:00 h
Tel.: +49 551 39-8395 (allg. Fragen)
Tel.: +49 (0)551 39-28655 (Fragen zu open access/Parallelpublikationen)
bbmed_AT_sub.uni-goettingen.de
[Bitte ersetzen Sie das "_AT_" durch ein "@", wenn Sie unsere E-Mail-Adressen verwenden.]