Analyse der In-vitro-Funktion verschiedener Anti-Siphon-Ventile in Kombination mit verschiedenen Differenzdruckventilen mit und ohne Bewegung

dc.contributor.advisorRohde, Veit Prof. Dr.
dc.contributor.authorRöhrig, Pauline
dc.date.accessioned2024-12-13T17:07:30Z
dc.date.available2025-02-12T00:50:04Z
dc.date.issued2024-12-13
dc.identifier.urihttp://resolver.sub.uni-goettingen.de/purl?ediss-11858/15675
dc.identifier.urihttp://dx.doi.org/10.53846/goediss-10902
dc.format.extent123de
dc.language.isodeude
dc.subject.ddc610de
dc.titleAnalyse der In-vitro-Funktion verschiedener Anti-Siphon-Ventile in Kombination mit verschiedenen Differenzdruckventilen mit und ohne Bewegungde
dc.typedoctoralThesisde
dc.title.translatedIn vitro performance of six combinations of adjustable differential pressure valves and fixed anti siphon devices with and without vertical motionde
dc.contributor.refereeRohde, Veit Prof. Dr.
dc.date.examination2025-01-15de
dc.description.abstractengShunt therapy using adjustable differential pressure valves combined with anti-siphon devices (ASDs) is a well-established approach for treating normal pressure hydrocephalus but continues to pose risks of severe complications, such as overdrainage. This study is aimed to analyze the flow characteristics of 3 commercial differential pressure valves paired with 2 different ASDs under static and dynamic conditions. The differential pressure valves proGAV 2.0 [PG], CertasPlus [CP], and HakimMedos [HM] were evaluated in combination with the gravity-regulated ASD (ShuntAssistant [SA]) and the flow-regulated ASD (SiphonGuard [SG]. Flow data was recorded at differential pressures ranging from 4 to 40 cmH₂O in both stationary setups and during vertical oscillations at frequencies of 2, 3, and 4 Hz. Additionally, the impact of inclination angles (90° vs. 60°) on flow rates was assessed. Results demonstrated that combinations with the gravity-regulated ASD allowed no or minimal flow at low differential pressures in static conditions, while a linear increase in flow occurred at higher pressures. Dynamic testing revealed significant flow increases for these combinations, proportional to oscillation frequency. In contrast, combinations with flow-regulated ASDs exhibited lower flow rates overall, and movement did not increase flow. Instead, the characteristic biphasic flow curve observed under static conditions was eliminated during motion. The distinct flow characteristics of the ASDs highlight the critical importance of selecting appropriate valve combinations for clinical applications. The findings provide valuable insights into tailoring shunt systems to individual patient needs and mitigating complications associated with movement. Further studies should build upon these results to optimize shunt systems and reduce the incidence of overdrainage in clinical practice.de
dc.contributor.coRefereeReuß, Bernhard Prof. Dr.
dc.subject.enghydrocephalusde
dc.identifier.urnurn:nbn:de:gbv:7-ediss-15675-0
dc.affiliation.instituteMedizinische Fakultätde
dc.subject.gokfullNeurochirurgie (PPN619876271)de
dc.description.embargoed2025-02-12de
dc.identifier.ppn191233402X
dc.notes.confirmationsentConfirmation sent 2024-12-13T19:45:01de


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record