Navigation ▼

Show simple item record

dc.contributor.advisor Nägerl, Hans Prof. Dr.
dc.contributor.author Albrecht, Anja Saskia
dc.date.accessioned 2020-02-19T11:54:18Z
dc.date.available 2020-03-04T23:50:03Z
dc.date.issued 2020-02-19
dc.identifier.uri http://hdl.handle.net/21.11130/00-1735-0000-0005-1327-A
dc.language.iso deu de
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subject.ddc 610 de
dc.title Messungen zur mechanischen Stabilität der Gleichgewichte von Knieendoprothesen: AEQUOS versus Mebio Scan-Knie de
dc.type doctoralThesis de
dc.title.translated Measurements of the mechanical equilibrium state of knee endoprostheses: AEQUOS versus Mebio Scan knee de
dc.contributor.referee Hubert, Jan PD Dr.
dc.date.examination 2020-02-26
dc.description.abstractger Die der Morphologie des natürlichen Kniegelenkes nachempfundene AEQUOS- Knieendoprothese wurde in einem Versuchsaufbau hinsichtlich ihrer biomechanischen Stabilität in Gleichgewichtspositionen im Vergleich mit der Mebio Scan-Knie Endoprothese unter Freischaltung aller Freiheitsgrade bei eingestellten Flexionswinkeln von 5° und 90° gemessen. Dabei zeigte sich, dass das AEQUOS-Knie eine Selbststabilisierung und ein Rollverhalten wie das natürliche Knie aufzeigte. Das Mebio Scan-Knie wies nur stabile Gleichgewichtszustände auf. Das AEQUOS-Knie zeigte stabile und instabile Gleichgewichte auf, wie sie für die Aufgabe des natürlichen Kniegelenkes, sowohl statische (Hocken) als auch kinematische (Aufstehen vom Stuhl) Funktionen zu erfüllen, notwendig sind. Durch Variationen des muskulären Kraftvektors konnten beim AEQUOS-Knie stabile und instabile Gleichgewichte erzeugt werden. Die Ergebnisse zeigen, dass das Prothesendesign das Gleichgewicht beeinflusst. de
dc.description.abstracteng In an experimental set-up, the biomechanical stability of the AEQUOS knee endoprosthesis and the Mebio Scan knee endoprosthesis in an equilibrium state were measured. The shape of the AEQUOS knee is based on the natural morphology of the human knee joint. Measurements were taken at 5° and 90° flexion. The AEQUOS knee showed a self-stabilizing and rolling mechanism like the natural knee. The Mebio Scan knee showed only stable states of equilibrium whereas the AEQUOUS knee showed stable and instable equilibriums. These stable and instable states are essential for the natural knee joint in order to fulfill the function of the knee in static (squat) and kinematic (rising up from a chair) matters. By varying the force vector of the muscle, it was possible to evoke stable and instable equilibriums for the AEQUOS knee. These results show that the design of the articulating surfaces of a knee endoprothesis determine its equilibrium. de
dc.subject.ger Biomechanik Kniegelenk de
dc.subject.ger Viergelenk des Kniegelenks de
dc.subject.ger Knieendoprothese de
dc.subject.ger AEQUOS de
dc.subject.eng biomechanics knee joint de
dc.subject.eng AEQUOS de
dc.subject.eng knee endoprosthesis de
dc.identifier.urn urn:nbn:de:gbv:7-21.11130/00-1735-0000-0005-1327-A-4
dc.affiliation.institute Medizinische Fakultät de
dc.subject.gokfull Medizin (PPN619874732) de
dc.description.embargoed 2020-03-04
dc.identifier.ppn 1690447826

Files in this item

This item appears in the following Collection(s)

Show simple item record