Zur Kurzanzeige

Auswirkung von drei konsekutiven Kryoenergieapplikationen auf die Bildung und Größe von Ablationsläsionen und die Koronararterien im sich entwickelnden Myokard

dc.contributor.advisorKrause, Ulrich PD Dr.
dc.contributor.authorAbreu da Cunha, Filipe
dc.date.accessioned2020-10-14T10:10:41Z
dc.date.available2020-11-03T23:50:03Z
dc.date.issued2020-10-14
dc.identifier.urihttp://hdl.handle.net/21.11130/00-1735-0000-0005-14B1-C
dc.identifier.urihttp://dx.doi.org/10.53846/goediss-8249
dc.identifier.urihttp://dx.doi.org/10.53846/goediss-8249
dc.language.isodeude
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subject.ddc610de
dc.titleAuswirkung von drei konsekutiven Kryoenergieapplikationen auf die Bildung und Größe von Ablationsläsionen und die Koronararterien im sich entwickelnden Myokardde
dc.typedoctoralThesisde
dc.title.translatedEffects of triple cryoenergy application on lesion formation and coronary arteries in the developing myocardiumde
dc.contributor.refereeKrause, Ulrich PD Dr.
dc.date.examination2020-10-27
dc.description.abstractengAims: To improve long-term outcome after cryoablation of SVT substrates, application of two and three consecutive freeze-thaw cycles has been performed. The effect of triple freeze-thaw cycles on lesion formation within developing myocardium and coronary arteries, however, has not been studied yet. Methods: In 8 piglets (mean age 15 weeks, weight 15-20 kg), a total of 30 cryolesions (three consecutive freeze-thaw cycles) were applied to the atrial aspect of both AV valve annuli (n=18) as well as to ventricular myocardium below the valves (n=12). Coronary angiography was performed before and after cryoenergy application. The animals were reevaluated by coronary angiography and intracoronary ultrasound after 48 hours. All hearts were removed for histological examination of the lesions subsequently. After staining (hematoxylin-eosin, desmin immunohistochemstry) lesions was measured by planimetry with a digital virtual miscroscope analysis system and volumes of the cryo-lesions were calculated. Results: Mean atrial lesion volume was 190.68 ± 167.53 mm3 (n=18) and mean ventricular lesion volume was 184.34 ± 107.42 mm3 (n=12). Compared with previously reported data on lesion volumes after single and double freeze-thaw cycles, lesions were significantly larger. Coronary arteries were unaffected on coronary angiography as well as on ICUS. No affection of coronary arteries was found on histological examination. Conclusion: Application of three consecutive freeze-thaw cycles resulted in increased lesion volume compared with single and double freeze-thaw cycles. No affection of the coronary arteries was evident. To evaluate the clinical benefit and safety of triple cryoenergy application for catheter ablation prospective randomized trials are required.de
dc.contributor.coRefereeZabel, Markus Prof. Dr.
dc.contributor.thirdRefereeOppermann, Martin Prof. Dr.
dc.subject.engcryoenergyde
dc.subject.engcatheter ablationde
dc.subject.engsupraventricular tachycardiade
dc.subject.engdeveloping myocardiumde
dc.subject.engcoronary arteryde
dc.identifier.urnurn:nbn:de:gbv:7-21.11130/00-1735-0000-0005-14B1-C-3
dc.affiliation.instituteMedizinische Fakultätde
dc.subject.gokfullMedizin (PPN619874732)de
dc.subject.gokfullPädiatrie / Neonatologie / Kinderchirurgie - Allgemein- und Gesamtdarstellungen (PPN619876093)de
dc.description.embargoed2020-11-03
dc.identifier.ppn1735627593


Dateien

Thumbnail

Das Dokument erscheint in:

Zur Kurzanzeige