• Deutsch
    • English
  • Deutsch 
    • Deutsch
    • English
  • Einloggen
Dokumentanzeige 
  •   Startseite
  • Naturwissenschaften, Mathematik und Informatik
  • Fakultät für Physik (inkl. GAUSS)
  • Dokumentanzeige
  •   Startseite
  • Naturwissenschaften, Mathematik und Informatik
  • Fakultät für Physik (inkl. GAUSS)
  • Dokumentanzeige
JavaScript is disabled for your browser. Some features of this site may not work without it.

Ratiometric fluorescence imaging and marker-free motion tracking of Langendorff perfused beating rabbit hearts

von Vineesh Kappadan
Dissertation
Datum der mündl. Prüfung:2020-07-14
Erschienen:2021-01-06
Betreuer:Prof. Dr. Ulrich Parlitz
Gutachter:Prof. Dr. Ulrich Parlitz
Gutachter:Prof. Dr. Jörg Enderlein
crossref-logoZum Verlinken/Zitieren: http://dx.doi.org/10.53846/goediss-8384

 

 

Dateien

Name:Thesis_Vineesh_Kappadan.pdf
Size:13.6Mb
Format:PDF
ViewOpen

Lizenzbestimmungen:


Zusammenfassung

Englisch

Optical mapping is a fluorescence based imaging technique used extensively in cardiac research to study the electrophysiological properties of isolated hearts kept at physiological conditions. The major limitation of optical mapping studies are the distortions of electrophysiological signals due to the contractile motion of the hearts. To reduce electrophysiological signal distortions due to the contractile motion artifacts, the mechanical motion has been suppressed in optical mapping experiments using electromechanical uncouplers such as Blebbistatin. Recent studies used marker-free numerical motion tracking and motion stabilization techniques to record electrophysiological parameters in the absence of electromechanical uncouplers and showed that contractile motion of the cardiac tissue is no longer a limitation in optical mapping studies. However, despite these developments, accurate measurements of quantities such as action potential duration (APD) and cardiac restitution are still challenging due to the residual motion artifacts present in the electrophysiological signals even after numerical motion tracking. A combination of marker-free motion tracking and ratiometric optical mapping technique is used in this thesis to minimize motion-related artifacts from contracting hearts. This combined experimental and numerical technique reduced motion artifacts significantly and hence, the combination is used to precisely measure APD, cardiac restitution and ventricular fibrillation frequencies from Langendorff perfused contracting and deforming rabbit hearts. A systematic comparison of these electrophysiological parameters in contracting and Blebbistatin-uncoupled conditions showed, on average, 27 ± 5% (N=5 hearts) shortening of APD in contracting hearts as compared to Blebbistatin-uncoupled hearts. Ventricular fibrillation frequency significantly increased in contracting hearts (13 ± 3.5 Hz) in comparison with Blebbistatin-uncoupled hearts (8 ± 1.5 Hz).
Keywords: Optical mapping; Langendorff perfused hearts; Motion tracking; Ratiometry; Action potential duration; Ventricular Fibrillation
 

Statistik

Hier veröffentlichen

Blättern

Im gesamten BestandFakultäten & ProgrammeErscheinungsdatumAutorBetreuer & GutachterBetreuerGutachterTitelTypIn dieser FakultätErscheinungsdatumAutorBetreuer & GutachterBetreuerGutachterTitelTyp

Hilfe & Info

Publizieren auf eDissPDF erstellenVertragsbedingungenHäufige Fragen

Kontakt | Impressum | Cookie-Einwilligung | Datenschutzerklärung
eDiss - SUB Göttingen (Zentralbibliothek)
Platz der Göttinger Sieben 1
Mo - Fr 10:00 – 12:00 h


Tel.: +49 (0)551 39-27809 (allg. Fragen)
Tel.: +49 (0)551 39-28655 (Fragen zu open access/Parallelpublikationen)
ediss_AT_sub.uni-goettingen.de
[Bitte ersetzen Sie das "_AT_" durch ein "@", wenn Sie unsere E-Mail-Adressen verwenden.]
Niedersächsische Staats- und Universitätsbibliothek | Georg-August Universität
Bereichsbibliothek Medizin (Nur für Promovierende der Medizinischen Fakultät)
Robert-Koch-Str. 40
Mon – Fri 8:00 – 24:00 h
Sat - Sun 8:00 – 22:00 h
Holidays 10:00 – 20:00 h
Tel.: +49 551 39-8395 (allg. Fragen)
Tel.: +49 (0)551 39-28655 (Fragen zu open access/Parallelpublikationen)
bbmed_AT_sub.uni-goettingen.de
[Bitte ersetzen Sie das "_AT_" durch ein "@", wenn Sie unsere E-Mail-Adressen verwenden.]