Show simple item record

Evaluierung des SOTOS (Silent Operating Theatre Optimisation System) bei roboterassistierten Operationen in der Urologie

dc.contributor.advisorTrojan, Lutz Prof. Dr.
dc.contributor.authorLeitsmann, Conrad
dc.date.accessioned2021-03-23T15:24:19Z
dc.date.available2021-04-08T00:50:10Z
dc.date.issued2021-03-23
dc.identifier.urihttp://hdl.handle.net/21.11130/00-1735-0000-0008-57C8-5
dc.identifier.urihttp://dx.doi.org/10.53846/goediss-8514
dc.language.isodeude
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subject.ddc610de
dc.titleEvaluierung des SOTOS (Silent Operating Theatre Optimisation System) bei roboterassistierten Operationen in der Urologiede
dc.typedoctoralThesisde
dc.title.translatedEvaluation of SOTOS (Silent Operating Thea tre Optimisation System) during robot‐assisted urological operationsde
dc.contributor.refereeTrojan, Lutz Prof. Dr.
dc.date.examination2021-04-01
dc.description.abstractengWe evaluate in a prospective and randomized study the use of the Silent Operating Theatre Optimization System in radical laparoscopic robot-assisted prostatovesiculectomy at our clinic. The present study consisted of two study groups operating with and without SOTOS.  In both groups, there were no significant differences in length of operation, intraoperative difficulty, radicality, complications, postoperative infections and lying time. In the SOTOS group, a trend towards shorter surgical times and optimal local tumor control during surgery was observed. An effect on the heart rates of the participants and thus on the feeling of stress could not be shown.  Measurements were carried out in the operating room at specific times of operation in terms of noise levels and their impact on the participants. Sound pressure levels and sound pressures were significantly lower compared to the control group in the SOTOS group. This is reflected over the entire duration of the operation. We were able to show that the use of SOTOS in radical laparoscopic robot-assisted prostatovesiculectomies allows a significant noise reduction in the operating room.de
dc.contributor.coRefereeBräuer, Anselm Prof. Dr.
dc.subject.engNoise pollutionde
dc.subject.engSOTOS©de
dc.subject.engDa vincide
dc.subject.engProstatectomyde
dc.subject.engRobotic surgeryde
dc.subject.engRobotic-assisted laparoscopic prostatectomy (RALP)de
dc.subject.engHealth riskde
dc.identifier.urnurn:nbn:de:gbv:7-21.11130/00-1735-0000-0008-57C8-5-5
dc.affiliation.instituteMedizinische Fakultätde
dc.subject.gokfullUrologie (PPN61987614X)de
dc.description.embargoed2021-04-08
dc.identifier.ppn175229243X


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record