Zur Kurzanzeige

Randschlussuntersuchung von Kompositfüllungen unter Einfluss von Brauchwasserdesinfektionsmitteln zahnärztlicher Behandlungseinheiten

dc.contributor.advisorZiebolz, Dirk PD Dr.
dc.contributor.authorFischer, Franziska
dc.date.accessioned2013-11-29T09:35:44Z
dc.date.available2013-12-10T23:50:05Z
dc.date.issued2013-11-29
dc.identifier.urihttp://hdl.handle.net/11858/00-1735-0000-0022-5C47-1
dc.identifier.urihttp://dx.doi.org/10.53846/goediss-4197
dc.language.isodeude
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/
dc.subject.ddc610de
dc.titleRandschlussuntersuchung von Kompositfüllungen unter Einfluss von Brauchwasserdesinfektionsmitteln zahnärztlicher Behandlungseinheitende
dc.typedoctoralThesisde
dc.title.translatedBorder seal investigation on resin composite fillings under the influence of disinfectants of dental unitsde
dc.contributor.refereeMausberg, Rainer Prof. Dr.
dc.date.examination2013-12-03
dc.description.abstractengThe border seal of resin composite fillings under the influence of disinfectants was investigated after dye penetration with methylene blue. One hundred and sixty human molars were divided in four different groups of disinfectants (n=40 Each group; CHX=C, Alpron®=A, Dentosept®=D) and water (=W) as the control group. The molars were filled in a class-II-cavities (one margin in enamel and one in dentin) with two different resin composites with correlating adhesive systems while using one of the disinfectants as a solution resulting in eight subgroups (n=20; Prime&Bond NT®+ Spektrum® and Optibond FL® + Herculite XVR Ultra®). The solution was sprayed over the cavity afterwards for two more minutes. Half of the teeth were stored in artificial saliva for 180 days and thermocycled (5°C/55°C, 2000cycles), half were stored for 24 hours. The marginal integrity was then investigated by dye penetration with methylene blue. The penetration was measured by two different readers. Statistical analysis of the data was carried out using ANOVA test (Significance level p < or = 0.0001). Disinfectants however showed no significant influence on either of the tested composites. The enamel site showed statistically significant less penetration than the dentin site. The specimen stored in artificial saliva showed statistically significant better results.de
dc.contributor.coRefereeKramer, Franz-Josef Prof. Dr. Dr.
dc.subject.gerBrauchwasserdesinfektionsmittelde
dc.subject.gerKompositfüllungende
dc.subject.engdisinfectantde
dc.subject.engresin compositede
dc.identifier.urnurn:nbn:de:gbv:7-11858/00-1735-0000-0022-5C47-1-9
dc.affiliation.instituteMedizinische Fakultätde
dc.subject.gokfullZahn-, Mund- und Kieferheilkunde - Allgemein- und Gesamtdarstellungen (PPN619876360)de
dc.description.embargoed2013-12-10
dc.identifier.ppn772878560
dc.creator.birthnameBoven


Dateien

Thumbnail

Das Dokument erscheint in:

Zur Kurzanzeige