• Deutsch
    • English
  • Deutsch 
    • Deutsch
    • English
  • Einloggen
Dokumentanzeige 
  •   Startseite
  • Naturwissenschaften, Mathematik und Informatik
  • Fakultät für Physik (inkl. GAUSS)
  • Dokumentanzeige
  •   Startseite
  • Naturwissenschaften, Mathematik und Informatik
  • Fakultät für Physik (inkl. GAUSS)
  • Dokumentanzeige
JavaScript is disabled for your browser. Some features of this site may not work without it.

A semi-microscopic model of synaptic transmission and plasticity

Ein semi-mikroskopisches Modell synaptischer Übertragung und Plastizität

von Julia Trommershäuser
Dissertation
Datum der mündl. Prüfung:2000-04-26
Erschienen:2000-08-28
Betreuer:Prof. Dr. Annette Zippelius
Gutachter:Prof. Dr. Annette Zippelius
Gutachter:Prof. Dr. Theo Geisel
crossref-logoZum Verlinken/Zitieren: http://dx.doi.org/10.53846/goediss-2733

 

 

Dateien

Name:thesis.pdf
Size:1.98Mb
Format:PDF
Description:Dissertation
ViewOpen

Lizenzbestimmungen:


Zusammenfassung

Englisch

A stochastic model of synaptic transmission has been designed on the basis of electro-physiological experiments. Monte Carlo simulations are performed which include presynaptic mechanisms of recruitment and calcium related release of vesicles, transmitter dynamics in the cleft and postsynaptic receptor kinetics. The model of presynaptic vesicle dynamics has been designed on the basis of experimentally observed patterns of synaptic depression (and facilitation) at the Calyx of Held in the mammalian auditory pathway. It comprises two types of vesicles, readily-releasable vesicles and in addition reluctantly-releasable vesicles, as well as facilitation of release as consequence of changes in the global residual calcium accumulating during previous repetitive activity. It is demonstrated that the transmitter dynamics within the cleft can be effectively modeled by a two-dimensional diffusion process, where absorbing boundary conditions reflect the effect of transmitter uptake by transporters and diffusion into extra-synaptic space. The transmitter diffusion within the cleft is slowed down compared to aqueous solution and an estimate of the effective diffusion coefficient is provided. The neurotransmitter interacts with individual spatially distributed receptors, which are included in the model on the basis of kinetic Markov models. The modeling steps of presynaptic vesicle dynamics, transmitter motion in the cleft and its interaction with postsynaptic receptors are combined to create a model of a single synaptic connection between two neurons. Postsynaptic responses are studied as function of input-frequency and possible physiological determinants. It is shown that the specific combination of release-probability, receptor desensitization and presynaptic release-machinery determines whether synaptic connections facilitate or depress and sets the range of input-rates, i.e. frequencies that can be transmitted towards the postsynaptic side.
Keywords: synaptic transmission; plasticity; stochastic process; Monte Carlo simulation; neuroscience
 

Statistik

Hier veröffentlichen

Blättern

Im gesamten BestandFakultäten & ProgrammeErscheinungsdatumAutorBetreuer & GutachterBetreuerGutachterTitelTypIn dieser FakultätErscheinungsdatumAutorBetreuer & GutachterBetreuerGutachterTitelTyp

Hilfe & Info

Publizieren auf eDissPDF erstellenVertragsbedingungenHäufige Fragen

Kontakt | Impressum | Cookie-Einwilligung | Datenschutzerklärung
eDiss - SUB Göttingen (Zentralbibliothek)
Platz der Göttinger Sieben 1
Mo - Fr 10:00 – 12:00 h


Tel.: +49 (0)551 39-27809 (allg. Fragen)
Tel.: +49 (0)551 39-28655 (Fragen zu open access/Parallelpublikationen)
ediss_AT_sub.uni-goettingen.de
[Bitte ersetzen Sie das "_AT_" durch ein "@", wenn Sie unsere E-Mail-Adressen verwenden.]
Niedersächsische Staats- und Universitätsbibliothek | Georg-August Universität
Bereichsbibliothek Medizin (Nur für Promovierende der Medizinischen Fakultät)
Robert-Koch-Str. 40
Mon – Fri 8:00 – 24:00 h
Sat - Sun 8:00 – 22:00 h
Holidays 10:00 – 20:00 h
Tel.: +49 551 39-8395 (allg. Fragen)
Tel.: +49 (0)551 39-28655 (Fragen zu open access/Parallelpublikationen)
bbmed_AT_sub.uni-goettingen.de
[Bitte ersetzen Sie das "_AT_" durch ein "@", wenn Sie unsere E-Mail-Adressen verwenden.]