• Deutsch
    • English
  • Deutsch 
    • Deutsch
    • English
  • Einloggen
Dokumentanzeige 
  •   Startseite
  • Medizin
  • Human- und Zahnmedizin
  • Dokumentanzeige
  •   Startseite
  • Medizin
  • Human- und Zahnmedizin
  • Dokumentanzeige
JavaScript is disabled for your browser. Some features of this site may not work without it.

Klinische Resultate dentaler Implantate im augmentierten Unterkiefer nach Zylinderinversionsplastik

Clinical results of dental implants in augmented mandibular ridge using Upside Down Cylinder Technique

von Thomas Lautenschläger
Dissertation
Datum der mündl. Prüfung:2017-04-25
Erschienen:2017-03-08
Betreuer:Prof. Dr. Dr. Wilfried Engelke
Gutachter:Prof. Dr. Dr. Wilfried Engelke
Gutachter:Prof. Dr. Philipp Franz Meyer-Marcotty
crossref-logoZum Verlinken/Zitieren: http://dx.doi.org/10.53846/goediss-6165

 

 

Dateien

Name:Dissertation_final_SUB_Webanzeige.pdf
Size:7.62Mb
Format:PDF
ViewOpen

Lizenzbestimmungen:


Zusammenfassung

Englisch

Purpose: In order to achieve good long-term results from dental implant therapy a sufficient amount of bone is needed around the correct implant position. Therefore, various procedures were introduced to augment the horizontally deficient mandibular ridge. The Upside Down Cylinder Technique makes use of localized autologous bone transfer in order to prevent the otherwise inevitable grafting procedure. In this retrospective study, clinical results and oral health related quality of life (OHRQoL) are being reported. Method: 44 Patients received horizontal bone augmentation and 29 Patients (22 female, seven male) with 43 implants could be followed up (dropout rate 34 %). The mean observation time was 93,6 +/- 36,3 months. Periimplant bone resorption (PBR), implant stability, periodontal probing depth (PPD), gingival recession (GR), implant survival, implant success and the state of OHRQoL were evaluated, respectively. Results: Within the observation period two implants were lost due to biological complications. This study shows an implant survival rate of 93 %. The implant success rate was 88,1 % according to Jahn/d’Hoedt criteria and 76,2 % according to Naert/Snauwaert criteria regarding patient level observation. Mean PBR was 2,57 +/- 1,93 mm, PPD accounted to 2,68 +/- 0,91 mm and GR was 0,75 +/- 1,26 mm. In order to assess patients OHRQOL, the Oral Health Impact Profile (OHIP) was used. Separated by prostetic indication classes, patients with installed FPD scored 9,2; patients with implant retained removable partial dentures and total prostheses scored 15,5 and 17,3; respectively. Corresponding scores were 30, 20 and 20 percentiles higher than median of reference values from non - treatment - seeking patients Conclusion: Upside Down Cylinder Technique delivers comparable implant long-term results compared to other autologous augmentation procedures without having to raise a flap for bone grafting. OHRQOL was high compared to reference values from non - treatment - seeking patients. Patients satisfaction and recommendation was also high. This study suggests a higher success rate in the posterior mandibular ridge.
Keywords: Dental implants; bone augmentation; mandibular ridge augmentation; oral health related quality of life; Upside Down Cylinder Technique; grafting technique; long-term success rate; bone grafting
Schlagwörter: Dentale Implantate; Knochenaugmentation; Kieferkammaufbau; Mundgesundheitsbezogene Lebensqualität; Zylinderinversionsplastik; Erfolgsrate Implantate
 

Statistik

Hier veröffentlichen

Blättern

Im gesamten BestandFakultäten & ProgrammeErscheinungsdatumAutorBetreuer & GutachterBetreuerGutachterTitelTypIn dieser FakultätErscheinungsdatumAutorBetreuer & GutachterBetreuerGutachterTitelTyp

Hilfe & Info

Publizieren auf eDissPDF erstellenVertragsbedingungenHäufige Fragen

Kontakt | Impressum | Cookie-Einwilligung | Datenschutzerklärung
eDiss - SUB Göttingen (Zentralbibliothek)
Platz der Göttinger Sieben 1
Mo - Fr 10:00 – 12:00 h


Tel.: +49 (0)551 39-27809 (allg. Fragen)
Tel.: +49 (0)551 39-28655 (Fragen zu open access/Parallelpublikationen)
ediss_AT_sub.uni-goettingen.de
[Bitte ersetzen Sie das "_AT_" durch ein "@", wenn Sie unsere E-Mail-Adressen verwenden.]
Niedersächsische Staats- und Universitätsbibliothek | Georg-August Universität
Bereichsbibliothek Medizin (Nur für Promovierende der Medizinischen Fakultät)
Robert-Koch-Str. 40
Mon – Fri 8:00 – 24:00 h
Sat - Sun 8:00 – 22:00 h
Holidays 10:00 – 20:00 h
Tel.: +49 551 39-8395 (allg. Fragen)
Tel.: +49 (0)551 39-28655 (Fragen zu open access/Parallelpublikationen)
bbmed_AT_sub.uni-goettingen.de
[Bitte ersetzen Sie das "_AT_" durch ein "@", wenn Sie unsere E-Mail-Adressen verwenden.]