In-vitro Performance verschiedener Kombinationen von verstellbaren Differenzdruckventilen mit fixen Anti-Siphon-Devices unter Berücksichtigung der räumlichen Position

In vitro performance of combinations of anti-siphon devices with differential pressure valves in relation to the spatial position

von Mareike Vanderheyden
Dissertation
Datum der mündl. Prüfung:2021-09-08
Erschienen:2021-08-02
Betreuer:Prof. Dr. Veit Rohde
Gutachter:Prof. Dr. Veit Rohde
Gutachter:Prof. Dr. Bernhard Reuss
crossref-logoZum Verlinken/Zitieren: http://dx.doi.org/10.53846/goediss-8762

 

 

Dateien

Name:Diss MV sub_1.pdf
Size:3.64Mb
Format:PDF
ViewOpen

Lizenzbestimmungen:


Zusammenfassung

Englisch

Programmable differential pressure valves (DPV) in combination with a fixed anti-siphon device (ASD) represent the present standard of care in preemtping overdrainage associated with ventriculoperitoneal shunting for hydrocephalus. Our aim was to provide comparative data of six combinations of two ASDs with different working principles in combination with three DP valves in an in vitro shunt laboratory achieving a better understanding of their flow characteristics and potential clinical application. We analyzed the flow performance of six possible combinations of three DP valves (CHPV [HM]; proGAV 2.0[PG]); Codman CertasPlus (CP) in combination with either a gravity-regulated (Shuntassistant [SA]) or a flow-regulated (SiphonGuard [SG]) ASD. A DP between 4 to 60 cmH2O was generated and the specific flow characteristics were measured. In addition, the three combinations with gravity-regulated ASDs were measured in defined spatial positions. Flow characteristics of the SA combinations corresponded to the DP in linear fashion and to the spatial position. Flow characteristics of the SG combinations were dependent upon the DP in a non-linear fashion and independent of the spatial position. Highest mean flow rate of the PG-SG- (HM-SG-) combination was 1.41 ± 0.24 ml/min (1.16 ± 0.06 ml/min). The meanflow rates sharply decreased with increasing inflow pressure and subsequently increased slowly up to 0.82 ± 0.26 ml/min (0.77 ±0.08 ml/min). In an experimental setup, all six tested device combinations were able to control the siphon effect which arises in the vertical position. The valve combinations prevent consecutive excessive flow to varying degrees. However, significant differences in flow characteristics can be seen, which might be relevant for their clinical application.
Keywords: hydrocephalus
 

Statistik

Hier veröffentlichen

Blättern

Im gesamten BestandFakultäten & ProgrammeErscheinungsdatumAutorBetreuer & GutachterBetreuerGutachterTitelTypIn dieser FakultätErscheinungsdatumAutorBetreuer & GutachterBetreuerGutachterTitelTyp

Hilfe & Info

Publizieren auf eDissPDF erstellenVertragsbedingungenHäufige Fragen

Kontakt | Impressum | Cookie-Einwilligung | Datenschutzerklärung | Barrierefreiheit
eDiss - SUB Göttingen (Zentralbibliothek)
Platz der Göttinger Sieben 1
Mo - Fr 10:00 – 12:00 h


Tel.: +49 (0)551 39-27809 (allg. Fragen)
Tel.: +49 (0)551 39-28655 (Fragen zu open access/Parallelpublikationen)
ediss_AT_sub.uni-goettingen.de
[Bitte ersetzen Sie das "_AT_" durch ein "@", wenn Sie unsere E-Mail-Adressen verwenden.]
Niedersächsische Staats- und Universitätsbibliothek | Georg-August Universität
Bereichsbibliothek Medizin (Nur für Promovierende der Medizinischen Fakultät)
Robert-Koch-Str. 40
Mon – Fri 8:00 – 24:00 h
Sat - Sun 8:00 – 22:00 h
Holidays 10:00 – 20:00 h
Tel.: +49 551 39-8395 (allg. Fragen)
Tel.: +49 (0)551 39-28655 (Fragen zu open access/Parallelpublikationen)
bbmed_AT_sub.uni-goettingen.de
[Bitte ersetzen Sie das "_AT_" durch ein "@", wenn Sie unsere E-Mail-Adressen verwenden.]