In-vitro Performance verschiedener Kombinationen von verstellbaren Differenzdruckventilen mit fixen Anti-Siphon-Devices unter Berücksichtigung der räumlichen Position

In vitro performance of combinations of anti-siphon devices with differential pressure valves in relation to the spatial position

by Mareike Vanderheyden
Doctoral thesis
Date of Examination:2021-09-08
Date of issue:2021-08-02
Advisor:Prof. Dr. Veit Rohde
Referee:Prof. Dr. Veit Rohde
Referee:Prof. Dr. Bernhard Reuss
crossref-logoPersistent Address: http://dx.doi.org/10.53846/goediss-8762

 

 

Files in this item

Name:Diss MV sub_1.pdf
Size:3.64Mb
Format:PDF
ViewOpen

The following license files are associated with this item:


Abstract

English

Programmable differential pressure valves (DPV) in combination with a fixed anti-siphon device (ASD) represent the present standard of care in preemtping overdrainage associated with ventriculoperitoneal shunting for hydrocephalus. Our aim was to provide comparative data of six combinations of two ASDs with different working principles in combination with three DP valves in an in vitro shunt laboratory achieving a better understanding of their flow characteristics and potential clinical application. We analyzed the flow performance of six possible combinations of three DP valves (CHPV [HM]; proGAV 2.0[PG]); Codman CertasPlus (CP) in combination with either a gravity-regulated (Shuntassistant [SA]) or a flow-regulated (SiphonGuard [SG]) ASD. A DP between 4 to 60 cmH2O was generated and the specific flow characteristics were measured. In addition, the three combinations with gravity-regulated ASDs were measured in defined spatial positions. Flow characteristics of the SA combinations corresponded to the DP in linear fashion and to the spatial position. Flow characteristics of the SG combinations were dependent upon the DP in a non-linear fashion and independent of the spatial position. Highest mean flow rate of the PG-SG- (HM-SG-) combination was 1.41 ± 0.24 ml/min (1.16 ± 0.06 ml/min). The meanflow rates sharply decreased with increasing inflow pressure and subsequently increased slowly up to 0.82 ± 0.26 ml/min (0.77 ±0.08 ml/min). In an experimental setup, all six tested device combinations were able to control the siphon effect which arises in the vertical position. The valve combinations prevent consecutive excessive flow to varying degrees. However, significant differences in flow characteristics can be seen, which might be relevant for their clinical application.
Keywords: hydrocephalus
 

Statistik

Publish here

Browse

All of eDissFaculties & ProgramsIssue DateAuthorAdvisor & RefereeAdvisorRefereeTitlesTypeThis FacultyIssue DateAuthorAdvisor & RefereeAdvisorRefereeTitlesType

Help & Info

Publishing on eDissPDF GuideTerms of ContractFAQ

Contact Us | Impressum | Cookie Consents | Data Protection Information | Accessibility
eDiss Office - SUB Göttingen (Central Library)
Platz der Göttinger Sieben 1
Mo - Fr 10:00 – 12:00 h


Tel.: +49 (0)551 39-27809 (general inquiries)
Tel.: +49 (0)551 39-28655 (open access/parallel publications)
ediss_AT_sub.uni-goettingen.de
[Please replace "_AT_" with the "@" sign when using our email adresses.]
Göttingen State and University Library | Göttingen University
Medicine Library (Doctoral candidates of medicine only)
Robert-Koch-Str. 40
Mon – Fri 8:00 – 24:00 h
Sat - Sun 8:00 – 22:00 h
Holidays 10:00 – 20:00 h
Tel.: +49 551 39-8395 (general inquiries)
Tel.: +49 (0)551 39-28655 (open access/parallel publications)
bbmed_AT_sub.uni-goettingen.de
[Please replace "_AT_" with the "@" sign when using our email adresses.]